{"id":5963,"date":"2020-11-22T09:19:20","date_gmt":"2020-11-22T08:19:20","guid":{"rendered":"https:\/\/www.medisafe.fr\/blog\/?p=5963"},"modified":"2025-05-27T14:38:23","modified_gmt":"2025-05-27T12:38:23","slug":"systeme-de-securite-incendie-en-erp-2","status":"publish","type":"post","link":"https:\/\/www.medisafe.fr\/blog\/systeme-de-securite-incendie-en-erp-2\/","title":{"rendered":"Le Syst\u00e8me de S\u00e9curit\u00e9 Incendie ou SSI"},"content":{"rendered":"<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<h2>Les cinq cat\u00e9gories de SSI<\/h2>\n<p>Il existe 5\u00a0cat\u00e9gories de syst\u00e8me de s\u00e9curit\u00e9 incendie en ERP, class\u00e9es par complexit\u00e9 d\u00e9croissante :<\/p>\n<ul>\n<li>Cat\u00e9gorie A<\/li>\n<li>Cat\u00e9gorie B<\/li>\n<li>Cat\u00e9gorie C<\/li>\n<li>Cat\u00e9gorie D<\/li>\n<li>Cat\u00e9gorie E<\/li>\n<\/ul>\n<p>Chaque ERP doit choisir la cat\u00e9gorie de SSI incendie qui lui convient en fonction du niveau de risque et le mieux reste de pr\u00e9voir le SSI lors de la cr\u00e9ation des locaux. Si le <b>risque incendie s\u2019av\u00e8re tr\u00e8s \u00e9lev\u00e9, il faut opter pour la cat\u00e9gorie A<\/b>. Et la cat\u00e9gorie E correspond ainsi au risque le moins \u00e9lev\u00e9.<\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<h2>D\u00e9finition des diff\u00e9rents dispositifs SSI<\/h2>\n<p>Le syst\u00e8me de s\u00e9curit\u00e9 incendie permet d&rsquo;<strong>alerter en cas de d\u00e9part de feu<\/strong> avec le <strong>SDI (Syst\u00e8me de d\u00e9tection incendie).<\/strong> Il d\u00e9ploie aussi automatiquement le <strong>processus de mise en s\u00e9curit\u00e9<\/strong> : le <strong>SMSI (Syst\u00e8me de Mise en S\u00e9curit\u00e9 Incendie)<\/strong>.<\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-textitle\">\n    <div class=\"textitle-inner cbo-container container--nomargin\">\n        <div class=\"textitle-title cbo-title-3 slide-up\">\n            <h3>\n                Le SSI de cat\u00e9gorie A            <\/h3>\n        <\/div>\n        <div class=\"textitle-content cbo-cms slide-up\">\n            <p>Il s\u2019agit du syst\u00e8me de s\u00e9curit\u00e9 incendie en ERP le plus complet. Il exige de respecter une <strong>norme incendie tr\u00e8s stricte afin de renforcer la pr\u00e9vention incendie<\/strong>. Il requiert notamment un plan d\u2019\u00e9vacuation plus performant incluant \u00e0 minima l\u2019installation d\u2019un d\u00e9tecteur optique de fum\u00e9e et d&rsquo;extincteurs d\u00e9di\u00e9s \u00e0 chaque type de feu. Cette solution de s\u00e9curit\u00e9 incendie comporte deux syst\u00e8mes\u00a0:<\/p>\n<p><strong>Le Syst\u00e8me de D\u00e9tection Incendie (SDI) inclut :<\/strong><\/p>\n<ul>\n<li>Des d\u00e9tecteurs automatiques (<strong>D\u00e9tecteurs Automatiques Incendies ou DAI<\/strong>) : ils permettent de d\u00e9tecter de la fum\u00e9e, de la chaleur, des flammes ;<\/li>\n<li>Des d\u00e9clencheurs manuels (<strong>D\u00e9clencheurs Manuels d&rsquo;Alarme ou DMA<\/strong>) : qui peuvent \u00eatre actionn\u00e9s par toute personne qui constate un d\u00e9part de feu ;<\/li>\n<li>Un <strong>E<\/strong><span style=\"font-size: 15px; font-style: normal;\"><strong>quipement de Contr\u00f4le et de Signalisation (ECS)<\/strong> : qui centralise les informations re\u00e7ues par les d\u00e9tecteurs et d\u00e9clencheurs et valide ou non le danger.<\/span><\/li>\n<\/ul>\n<p><strong>Le Syst\u00e8me de Mise en S\u00e9curit\u00e9 Incendie (SMSI) est compos\u00e9 de :<\/strong><\/p>\n<ul>\n<li style=\"font-size: 16px;\">Un\u00a0<strong><span style=\"font-size: 16px;\">Equipement d\u2019Alarme (EA)<\/span><\/strong>\u00a0: diffuseurs de signaux d&rsquo;alarme et de messages d&rsquo;alerte.<\/li>\n<li style=\"font-size: 16px;\">Des\u00a0<strong><span style=\"font-size: 16px;\">Dispositifs Actionn\u00e9s de S\u00e9curit\u00e9 (DAS)<\/span><\/strong><span style=\"font-size: 16px;\">.<\/span><\/li>\n<li style=\"font-size: 16px;\"><span style=\"font-size: 16px; font-style: normal; font-weight: 300;\">Un\u00a0<\/span><strong><span style=\"font-size: 16px; font-style: normal;\">Centralisateur de Mise en S\u00e9curit\u00e9 Incendie (CMSI)<\/span><\/strong><span style=\"font-size: 16px; font-style: normal; font-weight: 300;\">\u00a0: c&rsquo;est une unit\u00e9 centrale qui re\u00e7oit l&rsquo;information de l&rsquo;ECS et comprend trois parties :<\/span>\n<ul style=\"font-size: 16px; font-style: normal;\">\n<li style=\"font-size: 16px;\">Une\u00a0<strong>Unit\u00e9 de Signalisation (US)<\/strong>\u00a0: elle affiche l&rsquo;\u00e9tat des diff\u00e9rents\u00a0<span style=\"font-size: 16px; font-style: normal;\">DAS.<\/span><\/li>\n<li style=\"font-weight: 300; font-size: 16px;\">Une\u00a0<strong>Unit\u00e9 de Commandes Manuelles Centralis\u00e9es (UCMC)<\/strong>\u00a0: elle permet d&rsquo;agir \u00e0 distance sur ces dispositifs.<\/li>\n<li style=\"font-weight: 300; font-size: 16px;\">Une\u00a0<strong>Unit\u00e9 de Gestion d&rsquo;Alarme (UGA)<\/strong>\u00a0: elle contr\u00f4le les diffuseurs d&rsquo;alerte.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Le centralisateur de mise en s\u00e9curit\u00e9 incendie peut aussi comprendre une quatri\u00e8me partie : une <strong>Unit\u00e9 de Gestion Centralis\u00e9e des Issues de Secours (UGCIS)<\/strong>.<\/p>\n<p><span style=\"font-size: 16px; font-style: normal;\">Il est parfois n\u00e9cessaire d&rsquo;installer des <b>Dispositifs Adaptateurs de Commandes (DAC)<\/b> entre le centralisateur de mise en s\u00e9curit\u00e9 et les dispositifs actionn\u00e9s de s\u00e9curit\u00e9.<\/span><\/p>\n<p>Les dispositifs actionn\u00e9s de s\u00e9curit\u00e9 ou DAS ont trois fonctions, toutes destin\u00e9es \u00e0 limiter la propagation du feu et \u00e0 mettre en s\u00e9curit\u00e9 les personnes pr\u00e9sentes\u00a0 :<\/p>\n<ul>\n<li>le <b>compartimentage<\/b> :\u00a0 en fermant par exemple les portes ou clapets coupe-feu ;<\/li>\n<li>le <b>d\u00e9senfumage <\/b>: en ouvrant les volets ou en activant les moteurs de soufflage et d&rsquo;extraction ;<\/li>\n<li>l&rsquo;<b>\u00e9vacuation<\/b> : en d\u00e9verrouillant les issues de secours par exemple.<\/li>\n<\/ul>\n<p>Le SSI s\u00e9curit\u00e9 de cat\u00e9gorie A est toujours aliment\u00e9 par une source d&rsquo;\u00e9nergie normale et une source de s\u00e9curit\u00e9 secondaire avec une autonomie d\u00e9finie par une r\u00e9glementation incendie stricte.<\/p>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"cbo-textitle\">\n    <div class=\"textitle-inner cbo-container container--nomargin\">\n        <div class=\"textitle-title cbo-title-3 slide-up\">\n            <h3>\n                Le SSI de cat\u00e9gorie B            <\/h3>\n        <\/div>\n        <div class=\"textitle-content cbo-cms slide-up\">\n            <p>Il s\u2019apparente grandement au syst\u00e8me de s\u00e9curit\u00e9 incendie de cat\u00e9gorie\u00a0A, mais <b>sans le syst\u00e8me de d\u00e9tection incendie<\/b>. De <b>simples d\u00e9clencheurs manuels<\/b> branch\u00e9s au centralisateur de mise en s\u00e9curit\u00e9 incendie assurent la commande.<\/p>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"cbo-textitle\">\n    <div class=\"textitle-inner cbo-container container--nomargin\">\n        <div class=\"textitle-title cbo-title-3 slide-up\">\n            <h3>\n                Le SSI de cat\u00e9gorie\u00a0C            <\/h3>\n        <\/div>\n        <div class=\"textitle-content cbo-cms slide-up\">\n            <p>Cette cat\u00e9gorie de syst\u00e8me de s\u00e9curit\u00e9 incendie doit aussi \u00eatre aliment\u00e9e par deux sources. Il se compose d\u2019<b>un \u00e9quipement d\u2019alarme<\/b>\u00a0et de <b>dispositifs actionn\u00e9s de s\u00e9curit\u00e9<\/b>.<\/p>\n<p>L\u2019\u00e9quipement d&rsquo;alarme comporte\u00a0:<\/p>\n<ul>\n<li>Des <strong>d\u00e9clencheurs manuels<\/strong> ;<\/li>\n<li>Des <strong>Blocs Autonomes d\u2019Alarme Sonore\u00a0<span style=\"font-size: 16px; font-style: normal;\">(BAAS)<\/span><\/strong>\u00a0;<\/li>\n<li>Des <strong>diffuseurs sonores<\/strong>.<\/li>\n<\/ul>\n<p>Les dispositifs actionn\u00e9s de s\u00e9curit\u00e9 sont g\u00e9r\u00e9s au niveau d&rsquo;un<span style=\"font-size: 16px;\">\u00a0<\/span><b style=\"font-style: inherit;\">Dispositif de Commande avec Signalisation (DCS)<\/b><span style=\"font-size: 16px;\">.<\/span><\/p>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"cbo-textitle\">\n    <div class=\"textitle-inner cbo-container container--nomargin\">\n        <div class=\"textitle-title cbo-title-3 slide-up\">\n            <h3>\n                Le SSI de cat\u00e9gorie D            <\/h3>\n        <\/div>\n        <div class=\"textitle-content cbo-cms slide-up\">\n            <p>Le syst\u00e8me de s\u00e9curit\u00e9 de cat\u00e9gorie D se compose de\u00a0:<\/p>\n<ul>\n<li>Un <b>\u00e9quipement d\u2019alarme type 3<\/b> qui comprend des <b>d\u00e9clencheurs manuels<\/b> et des <b>blocs autonomes d\u2019alarme sonore<\/b>.<\/li>\n<li>Un syst\u00e8me de mise en s\u00e9curit\u00e9 incendie comportant\u00a0des <strong>dispositifs actionn\u00e9s de s\u00e9curit\u00e9,\u00a0<\/strong>un <b>dispositif de commandes manuelles regroup\u00e9es (DCMR) <\/b>qui peut d\u00e9clencher des DAS dans plusieurs secteurs et des <b>dispositifs adaptateurs de commandes <\/b>\u00a0qui re\u00e7oivent l&rsquo;ordre de commande de s\u00e9curit\u00e9 et la transmettent aux DAS.\u00a0<\/li>\n<\/ul>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"cbo-textitle\">\n    <div class=\"textitle-inner cbo-container container--nomargin\">\n        <div class=\"textitle-title cbo-title-3 slide-up\">\n            <h3>\n                Le SSI de cat\u00e9gorie E            <\/h3>\n        <\/div>\n        <div class=\"textitle-content cbo-cms slide-up\">\n            <p>Compos\u00e9e entre autres d\u2019une <a class=\"trygr-cat\" href=\"https:\/\/www.medisafe.fr\/securite-incendie\/alarme-incendie\">alarme incendie<\/a>, cette cat\u00e9gorie de syst\u00e8me de s\u00e9curit\u00e9 incendie reste la plus minimaliste de toutes. Elle est simplement constitu\u00e9e de\u00a0:<\/p>\n<ul>\n<li style=\"font-size: 16px;\">Un <b>bloc autonome d\u2019alarme incendie<\/b><\/li>\n<li>Des <b>d\u00e9clencheurs manuels<\/b><\/li>\n<li>Des <b>diffuseurs sonores<\/b><\/li>\n<\/ul>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"cbo-products\">\n\t<div class=\"products-inner cbo-container\">\n\t\t\n\t\t<div class=\"products-list products-listblock\">\n\t\t\t<a class='list-el' href='https:\/\/www.medisafe.fr\/alarme-de-type-4-flash-radio.html?channable=076bfe696400313638353672' target='_blank'><span class='el-inner'><span class='inner-picture cbo-picture-contain'><img loading='lazy' src='https:\/\/www.medisafe.fr\/blog\/wp-content\/themes\/medisafe\/library\/inc\/proxy.php?url=https%3A%2F%2Fwww.medisafe.fr%2Fmedia%2Fcache%2Fmedisafe_product_extra_large_thumbnail%2Fproduct%2F668-cover-image-alarme-de-type-4-flash-radio.png' alt='Alarme de Type 4 Flash Radio' \/><\/span><h3 class='inner-title cbo-title-3'>Alarme de Type 4 Flash Radio<\/h3><span class='inner-content'>Alarme de Type 4 Flash Radio &#8211; Axendis,<\/span><span class='inner-priceht'>179.95 \u20ac HT<\/span><span class='inner-pricettc'>215.94 \u20ac TTC<\/span><\/span><\/a><a class='list-el' href='https:\/\/www.medisafe.fr\/alarme-de-type-4-a-pile.html?channable=076bfe696400313638353773' target='_blank'><span class='el-inner'><span class='inner-picture cbo-picture-contain'><img loading='lazy' src='https:\/\/www.medisafe.fr\/blog\/wp-content\/themes\/medisafe\/library\/inc\/proxy.php?url=https%3A%2F%2Fwww.medisafe.fr%2Fmedia%2Fcache%2Fmedisafe_product_extra_large_thumbnail%2Fproduct%2F667-cover-image-alarme-de-type-4-a-pile.png' alt='Alarme Type 4 autonome Axendis' \/><\/span><h3 class='inner-title cbo-title-3'>Alarme Type 4 autonome Axendis<\/h3><span class='inner-content'>Alarme Type 4 autonome Axendis &#8211; Axendis,<\/span><span class='inner-priceht'>89.95 \u20ac HT<\/span><span class='inner-pricettc'>107.94 \u20ac TTC<\/span><\/span><\/a><a class='list-el' href='https:\/\/www.medisafe.fr\/alarme-autonome-4-251330.html?channable=076bfe69640032333934303b' target='_blank'><span class='el-inner'><span class='inner-picture cbo-picture-contain'><img loading='lazy' src='https:\/\/www.medisafe.fr\/blog\/wp-content\/themes\/medisafe\/library\/inc\/proxy.php?url=https%3A%2F%2Fwww.medisafe.fr%2Fmedia%2Fcache%2Fmedisafe_product_extra_large_thumbnail%2Fproduct%2F9234-cover-image-alarme-autonome-4-251330.png' alt='Alarme type 4 autonome Orexa' \/><\/span><h3 class='inner-title cbo-title-3'>Alarme type 4 autonome Orexa<\/h3><span class='inner-content'>Alarme type 4 autonome Orexa &#8211; Cordia,<\/span><span class='inner-priceht'>82.95 \u20ac HT<\/span><span class='inner-pricettc'>99.54 \u20ac TTC<\/span><\/span><\/a><a class='list-el' href='https:\/\/www.medisafe.fr\/alarme-type-4-radio-251333.html?channable=076bfe69640032333934313c' target='_blank'><span class='el-inner'><span class='inner-picture cbo-picture-contain'><img loading='lazy' src='https:\/\/www.medisafe.fr\/blog\/wp-content\/themes\/medisafe\/library\/inc\/proxy.php?url=https%3A%2F%2Fwww.medisafe.fr%2Fmedia%2Fcache%2Fmedisafe_product_extra_large_thumbnail%2Fproduct%2F9237-cover-image-alarme-type-4-radio-251333.png' alt='Alarme type 4 radio Orexa' \/><\/span><h3 class='inner-title cbo-title-3'>Alarme type 4 radio Orexa<\/h3><span class='inner-content'>Alarme type 4 radio Orexa &#8211; Cordia,<\/span><span class='inner-priceht'>264.95 \u20ac HT<\/span><span class='inner-pricettc'>317.94 \u20ac TTC<\/span><\/span><\/a><a class='list-el' href='https:\/\/www.medisafe.fr\/alarme-type-4-flash-251328.html?channable=076bfe6964003233393339c3' target='_blank'><span class='el-inner'><span class='inner-picture cbo-picture-contain'><img loading='lazy' src='https:\/\/www.medisafe.fr\/blog\/wp-content\/themes\/medisafe\/library\/inc\/proxy.php?url=https%3A%2F%2Fwww.medisafe.fr%2Fmedia%2Fcache%2Fmedisafe_product_extra_large_thumbnail%2Fproduct%2F9232-cover-image-alarme-type-4-flash-251328.jpeg' alt='Alarme type 4 autonome Orexa avec flash int\u00e9gr\u00e9' \/><\/span><h3 class='inner-title cbo-title-3'>Alarme type 4 autonome Orexa avec flash int\u00e9gr\u00e9<\/h3><span class='inner-content'>Alarme type 4 autonome Orexa avec flash int\u00e9gr\u00e9 &#8211; Cordia,<\/span><span class='inner-priceht'>112.95 \u20ac HT<\/span><span class='inner-pricettc'>135.54 \u20ac TTC<\/span><\/span><\/a><a class='list-el' href='https:\/\/www.medisafe.fr\/alarme-autonome-type-4.html?channable=076bfe696400313638353571' target='_blank'><span class='el-inner'><span class='inner-picture cbo-picture-contain'><img loading='lazy' src='https:\/\/www.medisafe.fr\/blog\/wp-content\/themes\/medisafe\/library\/inc\/proxy.php?url=https%3A%2F%2Fwww.medisafe.fr%2Fmedia%2Fcache%2Fmedisafe_product_extra_large_thumbnail%2Fproduct%2F2134-cover-image-alarme-autonome-type-4.jpeg' alt='Alarme autonome type 4' \/><\/span><h3 class='inner-title cbo-title-3'>Alarme autonome type 4<\/h3><span class='inner-content'>Alarme autonome type 4 &#8211; Cordia,<\/span><span class='inner-priceht'>129.95 \u20ac HT<\/span><span class='inner-pricettc'>155.94 \u20ac TTC<\/span><\/span><\/a>\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-readmore\">\n    <div class=\"readmore-inner cbo-container\">\n        <div class=\"readmore-box slide-up\">\n            <div class=\"box-label cbo-title-3\">\n                <i class=\"icon icon--devis\"><\/i>\n                Lire aussi\n            <\/div>\n            <div class=\"box-content\">\n                <a href=\"https:\/\/www.medisafe.fr\/blog\/\/comment-utiliser-un-extincteur\/\" target=\"\">\n                    Comment utiliser un extincteur ?                <\/a>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>\n\n\n    <section class=\"cbo-picture\">\n        <div class=\"picture-inner cbo-container\">\n            <div class=\"cbo-picture-contain slide-up\">\n                <img\n                    decoding=\"async\"\n                    src=\"https:\/\/www.medisafe.fr\/blog\/wp-content\/uploads\/2022\/03\/systeme-de-securite-incendie-1-1.png\"\n                    srcset=\"https:\/\/www.medisafe.fr\/blog\/wp-content\/uploads\/2022\/03\/systeme-de-securite-incendie-1-1.png 320w, https:\/\/www.medisafe.fr\/blog\/wp-content\/uploads\/2022\/03\/systeme-de-securite-incendie-1-1.png 768w, https:\/\/www.medisafe.fr\/blog\/wp-content\/uploads\/2022\/03\/systeme-de-securite-incendie-1-1.png 1024w\"\n                    alt=\"systeme de securite incendie\" sizes=\"auto, 100vw\"\n                    loading=\"lazy\"\n                    width=\"1000\" height=\"800\"\n                >\n            <\/div>\n                    <\/div>\n    <\/section>\n\n\n<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<p>R\u00e9sum\u00e9 du fonctionnement du Syst\u00e8me de S\u00e9curit\u00e9 Incendie<\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<h2>\u00c9quiper son entreprise contre les incendies<\/h2>\n<p>Le Code du travail a d\u00e9fini une <strong>r\u00e9glementation incendie pour garantir la s\u00e9curit\u00e9 des ERP<\/strong>. Il vous sera imp\u00e9ratif d&rsquo;\u00e9quiper votre \u00e9tablissement professionnel d&rsquo;un d\u00e9tecteur de fum\u00e9e \u00e0 chaque \u00e9tage. En cela, il s&rsquo;av\u00e8re imp\u00e9ratif de limiter tous les \u00e9l\u00e9ments susceptibles de d\u00e9clencher un incendie.<\/p>\n<p>En pr\u00e9vention, vous pouvez installer un <a class=\"trygr-cat\" href=\"https:\/\/www.medisafe.fr\/securite-incendie\/extincteur\/abc-poudre\/extincteur-poudre-abc-6kg.html\">extincteur\u00a06kg<\/a>, pour que la protection du personnel, des locaux et des biens mat\u00e9riels soit assur\u00e9e en cas d\u2019incendie. Cet extincteur \u00e0 poudre ABC que ce soit en pression permanente ou pression auxiliaire, convient \u00e0 la plupart des cas d&rsquo;incendie, il est un \u00e9quipement de base de toutes les entreprises.<\/p>\n<p>Vous pouvez choisir l\u2019<a class=\"trygr-cat\" href=\"https:\/\/www.medisafe.fr\/securite-incendie\/extincteur\">extincteur<\/a> selon les diff\u00e9rents risques \u00e9valu\u00e9s au pr\u00e9alable sur un <a class=\"trygr-cat\" href=\"https:\/\/www.medisafe.fr\/securite-incendie\/accessoires-incendie\/registre-de-securite\">registre de s\u00e9curit\u00e9<\/a>. Ce peut aussi \u00eatre un extincteur\u00a01kg si la surface \u00e0 prot\u00e9ger est restreinte ou pour un v\u00e9hicule professionnel. Par ailleurs, un extincteur \u00e0 eau peut s&rsquo;av\u00e9rer pratique pour votre <strong>SSI incendie<\/strong>. En outre, les <a class=\"trygr-cat\" href=\"https:\/\/www.medisafe.fr\/securite-incendie\/alarme-incendie\/detecteurs-de-fumee\">d\u00e9tecteurs de fum\u00e9e<\/a> demeurent indispensables dans les bureaux de petites PME par exemple.<\/p>\n<p>Toujours dans le but de garantir une s\u00e9curit\u00e9 incendie optimale \u00e0 tous les salari\u00e9s, une consigne de s\u00e9curit\u00e9 incendie  doit \u00eatre compl\u00e9t\u00e9e et mise \u00e0 jour r\u00e9guli\u00e8rement, et un plan d\u2019\u00e9vacuation appropri\u00e9 sera affich\u00e9 \u00e0 des endroits strat\u00e9giques de l\u2019\u00e9tablissement. Les employ\u00e9s seront form\u00e9s \u00e0 utiliser correctement les robinets d\u2019incendie arm\u00e9s. Il est m\u00eame conseill\u00e9 d\u2019organiser des simulations d\u2019\u00e9vacuation pour que tout le monde puisse \u00eatre bien pr\u00e9par\u00e9 \u00e0 affronter un tel incident. Chaque salari\u00e9 doit conna\u00eetre la r\u00e9glementation incendie ainsi que les consignes \u00e9vacuation incendie.<\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<h2>Effectuer une formation incendie en entreprise<\/h2>\n<p>Pour assurer la s\u00e9curit\u00e9 incendie de tous, la loi exige au chef d\u2019\u00e9tablissement ERP de former ses salari\u00e9s (Art 231-3-1). Chaque employ\u00e9 doit suivre une formation en s\u00e9curit\u00e9 adapt\u00e9e \u00e0 son poste de travail (avec un plan d&rsquo;intervention). Autrement, le <b>chef d\u2019entreprise endosse toute responsabilit\u00e9 p\u00e9nale en cas de blessure ou de d\u00e9c\u00e8s<\/b> d\u00fb \u00e0 un incendie au travail. L\u2019utilisation de mat\u00e9riel incendie peut \u00eatre d\u2019une grande utilit\u00e9 lors de la formation en s\u00e9curit\u00e9 incendie.<\/p>\n<p>L\u2019objectif consiste \u00e0 pr\u00e9venir les incendies et de savoir comment r\u00e9agir en cas de d\u00e9part de feu.<\/p>\n<p>Selon le Code du Travail, la formation en s\u00e9curit\u00e9 incendie incombe \u00e0 l\u2019employeur. <b>Elle doit \u00eatre reconduite tous les 6 mois<\/b>. Le plan d\u2019\u00e9vacuation et l\u2019utilisation des extincteurs constituent les principaux sujets de chaque formation SSI incendie.<\/p>\n<p>Le registre de s\u00e9curit\u00e9 et \u00e0 revoir \u00e0 ce moment l\u00e0.<\/p>\n<p><strong>D\u00e9couvrez une vid\u00e9o illustrant le fonctionnement du Syst\u00e8me de S\u00e9curit\u00e9 Incendie pour la formation SSIAP (Service de S\u00e9curit\u00e9 et d&rsquo;Assistance \u00e0 Personnes)<\/strong><\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<p><iframe loading=\"lazy\" width=\"800\" height=\"400\" src=\"https:\/\/www.youtube.com\/embed\/g5xyjsOMqmk\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe><\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>\n\n<section class=\"cbo-remember\">\n    <div class=\"remember-inner cbo-container\">\n        <div class=\"remember-box\">\n            <div class=\"box-title cbo-title-2 slide-up\">\n                <i class=\"icon icon--box-success\"><\/i>\n                <h2 class=\"cbo-title-2\">\n                    Ce qu\u2019il faut retenir\n                <\/h2>\n            <\/div>\n            <div class=\"box-content cbo-cms slide-up\">\n                <ul>\n<li><b>D\u00e9finition du SSI<\/b> : ensemble d&rsquo;\u00e9quipements permettant de recueillir les informations concernant un \u00e9ventuel danger, les traiter et actionner la mise en s\u00e9curit\u00e9 d&rsquo;un b\u00e2timent. Il facilite l&rsquo;\u00e9vacuation des personnes, limite la propagation du feu et favorise l&rsquo;intervention des pompiers.\u00a0<\/li>\n<li><b>Le Syst\u00e8me de D\u00e9tection d&rsquo;Incendie<\/b> : c&rsquo;est le premier \u00e9l\u00e9ment du SSI. Les\u00a0<span style=\"font-size: 15px; font-style: normal; font-weight: 300;\">dispositifs de d\u00e9tection sont\u00a0<\/span>automatiques (DAI) ou manuels (DMA). Les d\u00e9tecteurs automatiques fonctionnent de fa\u00e7on autonome (d\u00e9tecteur ionique, optiques de fum\u00e9es, thermiques, optiques de flammes). Le d\u00e9clencheur manuel dispos\u00e9 \u00e0 chaque niveau dans des zones de circulation permet aux personnes pr\u00e9sentes d&rsquo;alerter en cas de d\u00e9part de feu.<\/li>\n<li><b>L&rsquo;Equipement de contr\u00f4le et de signalisation (ECS)<\/b> : il re\u00e7oit l&rsquo;information du syst\u00e8me de d\u00e9tection incendie, valide ou non le danger, localise la zone concern\u00e9e.<\/li>\n<li><b>Le Centralisateur de mise en s\u00e9curit\u00e9 incendie (CMSI)<\/b> : il est connect\u00e9 \u00e0 l&rsquo;ECS et g\u00e8re les alertes sonores diffus\u00e9es dans l&rsquo;\u00e9tablissement et les dispositifs permettant s&rsquo;assurer la s\u00e9curit\u00e9 (appel\u00e9s Dispositifs Actionn\u00e9s de S\u00e9curit\u00e9 ou DAS) tels que les portes coupe-feu pour limiter la propagation de l&rsquo;incendie, les moteurs de soufflage pour d\u00e9senfumer, le d\u00e9verrouillage des portes de secours pour faciliter l&rsquo;\u00e9vacuation&#8230;<\/li>\n<\/ul>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"cbo-text\">\n\t<div class=\"text-inner cbo-container\">\n\t\t<div class=\"cbo-cms\">\n\t\t\t<p>Conclusion : la mise en place d\u2019un <strong>syst\u00e8me de s\u00e9curit\u00e9 incendie ad\u00e9quat au sein de votre ERP<\/strong> ne constitue pas seulement une <b>obligation, c\u2019est un devoir<\/b>. Selon le niveau de risque incendie des lieux, il faut choisir la bonne cat\u00e9gorie de SSI incendie. En tant que chef d\u2019\u00e9tablissement, vous devez octroyer une <b>formation en s\u00e9curit\u00e9 incendie \u00e0 l\u2019ensemble du personnel<\/b>. Bien \u00e9videmment, la mise en place d&rsquo;\u00e9quipements de pr\u00e9vention incendie comme des extincteurs et des d\u00e9tecteurs de fum\u00e9e reste une priorit\u00e9. Sp\u00e9cialiste en s\u00e9curit\u00e9 incendie, Medisafe vous propose justement une <strong>large gamme de mat\u00e9riel incendie de premi\u00e8re qualit\u00e9<\/strong>. <!-- \/wp:html --><\/p>\n<p><!-- wp:paragraph --><\/p>\n<p>&nbsp;<\/p>\n\t\t<\/div>\n\t<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez comment fonctionne un Syst\u00e8me de S\u00e9curit\u00e9 Incendie et quelles sont les obligations d&rsquo;une entreprise.<\/p>\n","protected":false},"author":18,"featured_media":621,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[87],"tags":[215],"class_list":["post-5963","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-secourir","tag-alarmes-type-4"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/posts\/5963","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/comments?post=5963"}],"version-history":[{"count":15,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/posts\/5963\/revisions"}],"predecessor-version":[{"id":34237,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/posts\/5963\/revisions\/34237"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/media\/621"}],"wp:attachment":[{"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/media?parent=5963"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/categories?post=5963"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.medisafe.fr\/blog\/wp-json\/wp\/v2\/tags?post=5963"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}